The buttons don’t do anything
Check the HOLD switch (there’s one on the body and one on the handle). It locks the controls.
I can’t find 25p
Set full menu → Project → Rec Format → Frequency to 25. The camera may restart.
The picture looks flat and grey
You’re in Cine EI or Flexible ISO. Choose a LUT under Base Look/LUT on the Monitoring status screen, and check LUT On/Off is on for the viewfinder.
My footage has the LUT baked in
Shooting → LUT On/Off → Internal Rec is on. Turn it off.
I can’t change the ISO
In Cine EI you change the Exposure Index, not the ISO. Switch to Flexible ISO or Custom if you want normal ISO.
Recording won’t start
The card is full, or it needs restoring. Swap the card, or follow the on-screen prompt to restore it.
“Media Near Full” or “Media Full”
Swap the card soon, or straight away for “Media Full”.
“Media Temperature High”
The CFexpress card is too hot. Swap it, or let it cool down.
There’s no sound
- Check the AUDIO LEVEL dials aren’t turned right down.
- S&Q and Interval Rec don’t record sound.
- For XLR mics, check the INPUT switch, and use MIC+48V if the mic needs phantom power.
The sound is distorted or noisy
Distorted means the level is too high, so turn the AUDIO LEVEL dial down. Noisy means it’s too low, so turn it up.
The fan is audible on my interview
Set Technical → Fan Control to Off in Rec.
The battery runs out fast
That’s normal in the cold. Keep spares warm.
Still stuck?
As a last resort, use full menu → Maintenance → All Reset → Reset. Imported LUTs and scene files are kept. Or call us on 0141 420 2053. We’re here Mon–Fri 8:30–5, and out-of-hours help is available through the same number.